Humidity of Air and Other Gases

Basis: IAPWS saturation pressures; Greenspan/Hardy and Hyland (NIST) enhancement factors; WMO psychrometer

Converts between relative humidity, dew and frost point, wet-bulb temperature, mixing ratio, absolute humidity, ppm and enthalpy for air or another gas at any pressure, with uncertainty, pressure dew point and a psychrometric chart.

Input
Result
updates as you type
Reload
restores the example

Humidity of air or another gas: type any one humidity value and all the others follow. The radio button shows which value is given (yellow); every green value can be typed over to become the given one.

Mode
Units

1 Conditions

Air – basic: air at the standard atmosphere, 1013.25 hPa. Switch to Advanced for other pressures, other gases and more quantities.

Give

Δ°C

    2 Humidity: type any one value

    Wet bulb

    %
    °C
    °C
    %
    °C
    ppm
    ppm
    g/kg
    %

    ± values: the largest change of each result when the given value and T move by their uncertainties (empty = none), as the Vaisala calculator shows them.

      3 Saturation and gas properties

      Saturation pressure of pure water ew(T)hPa
      Enhancement factor f–
      Saturation vapour pressure in the gas Pws = f·ew(T)hPa
      Compressibility factor of the humid gas Z = 1 + B·P/(R·T) + (C − B2)·(P/(R·T))2–
      Density of the humid gas ρ = P·M/(Z·R·T)
      Specific volume per kg humid gas v = 1/ρ
      Specific volume per kg dry gas vdry = (1 + x)/ρm³/kg

      4 Dew point at another pressure

      hPa (A)
      Water vapour pressure at P₂ Pw2 = Pw·P2/PhPa
      Dew point at P₂ f·ew(Td2) = Pw2°C
      Dew/frost point at P₂ f·e(Tdf2) = Pw2°C

      Compressing or expanding the gas keeps its composition, so the water vapour pressure scales with the total pressure. Typical use: the dew point of compressed (instrument) air at line pressure against the same air at atmospheric pressure.

      5 Psychrometric chart

      Calculation basis

      Wet bulb: which one?
      • Thermodynamic (adiabatic saturation temperature): the temperature the gas reaches when water evaporates into it until it is saturated, with no heat from outside, from the energy balance h(T, x) + (xs − x)·hc(Tw) = h(Tw, xs). Use it for evaporative coolers, cooling towers, saturators and quench calculations, and for any gas. Below 0 °C the wet surface is ice (ice bulb).
      • Psychrometer (WMO): what a ventilated wet-bulb thermometer (Assmann psychrometer) reads in air, Pw = f·ew(Tw) − 6.53·10−4·(1 + 0.000944·tw)·P·(T − Tw) K−1, over ice 5.75·10−4 K−1 (WMO-No. 8, Annex 4.B). Use it to evaluate a psychrometer reading. The coefficient is for air; for other gases the reading depends on heat and mass transfer and this equation does not apply.
      • In air the two differ by about 0.1 °C (the thermometer reads slightly higher). Vaisala's calculator uses a psychrometer coefficient 6.62·10−4·(1 + 0.00115·tw) for every gas, which gives 16.34 °C at 23 °C and 50 %rh against 16.30 °C (WMO) and 16.23 °C (thermodynamic).
      Equations
      1. Saturation pressure of pure water ew: IAPWS SR1-86(1992) (Wagner & Pruß), 0.01 °C to the critical point 373.946 °C; supercooled water below 0.01 °C: Sonntag (1990), scaled to meet IAPWS at the triple point. Over ice ei: IAPWS R14-08(2011), down to −100 °C here.
      2. Enhancement factor f (water vapour in a gas reaches a slightly higher partial pressure than over pure water; Pws = f·e): air up to 2 MPa: Greenspan (1975) with the ITS-90 coefficients of Hardy (1998), as used by Vaisala; air above 2 MPa (−50 to 90 °C): Hyland's (1975) virial equation A-4 with his coefficients for air, of which Greenspan's equations are a fit, so f is continuous at 2 MPa; all other gases: the same equation A-4 with second virial coefficients only: water Bww (Harvey & Lemmon 2004), gas Bgg (generalized correlation, Perry Eq. 4-203), water–gas Bgw from first-principles correlations (N₂, O₂, Ar, air: Harvey & Huang 2007; CO₂: Wheatley & Harvey 2011; CH₄: Akin-Ojo et al. 2006; H₂: Hodges et al. 2004) or, for SF₆ and the Properties compounds, estimated with the generalized correlation (Perry Eqs. 4-214 to 4-218, kij = 0.226 fitted by us to the five published gases, within ±70 cm³/mol); gas solubility in the condensed water: Henry's constants of IAPWS G7-04.
      3. Relative humidity (WMO definition): RH = Pw/(f·ew(T)), over water also below 0 °C; RHi over ice below 0 °C. Dew/frost point: the dew point when it is at or above 0 °C, otherwise the frost point (over ice).
      4. Mixing ratio x = (Mw/Mg)·Pw/(P − Pw), Mw = 18.015268 g/mol; air M = 28.9586 g/mol (Lemmon et al. 2000).
      5. Real gas: Z = 1 + B·P/(RT) + (C − B²)·(P/(RT))², B = ΣyiyjBij; C for air from Hyland (−50 to 110 °C), otherwise 0. Absolute humidity and density use Z.
      6. Enthalpy per kg dry gas: h = hg(T) + x·hv(T) + hR; dry gas from its ideal-gas cp(T) (Properties data), water vapour from IAPWS-IF97 (ideal gas), real-gas correction hR = P·(B − T·dB/dT). Zero: dry gas at 0 °C and 1 atm, liquid water at 0.01 °C (as ASHRAE and Vaisala). BTU/lb is a unit conversion only (US charts often start dry air at 0 °F: subtract 7.68 BTU/lb for that datum).
      7. Elevation: U.S. Standard Atmosphere 1976 (ISO 2533), troposphere up to 11 km.
      Accuracy and differences from the Vaisala calculator
      1. Air: checked against CoolProp's humid-air model (ASHRAE RP-1485): mixing ratio, specific volume within 0.06 %, dew point within 0.01 °C, wet bulb within 0.03 °C, enthalpy within 0.1 kJ/kg (−20 to 90 °C, up to 1 MPa).
      2. Vaisala extends Sonntag's equation to 1200 °C (valid to 100 °C) and sets f = 1 above 2 MPa and for gases other than air and nitrogen; it treats the gas as ideal and gives the specific volume per kg of humid gas only. Here IAPWS is used up to the critical point, f is computed for every gas and pressure, and the gas is real.
      3. Above about 1 MPa (2 MPa for air) the enhancement factor is less certain, because third virial coefficients are known only for air; the tool warns.

      Sources

      1. NIST / CODATA, “Molar gas constant R (exact since the 2019 SI redefinition)”, The NIST Reference on Constants, Units, and Uncertainty, 2018sourcearchived copyread 2026-11-20Gas constant R = 8.314462618 J/(mol·K).
      2. IAPWS, “Revised Release on the IAPWS Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam, R7-97(2012)”, International Association for the Properties of Water and Steam, 2012sourcearchived copyread 2026-11-20Enthalpy of water vapour (ideal gas, region 2 at 1 Pa) and of liquid water at the wet bulb (region 1).
      3. I. H. Bell, J. Wronski, S. Quoilin, V. Lemort, “Pure and Pseudo-pure Fluid Thermophysical Property Evaluation and the Open-Source Thermophysical Property Library CoolProp”, Ind. Eng. Chem. Res. 53 (6), 2498–2508, 2014sourceread 2026-11-21Independent check of air (HAPropsSI, ASHRAE RP-1485 humid-air model): mixing ratio, dew point, wet bulb, specific volume, enthalpy at six states (tests).
      4. B. E. Poling, J. M. Prausnitz, J. P. O'Connell, “The Properties of Gases and Liquids, 5th ed., Appendix A”, McGraw-Hill, New York, 2001read 2026-11-21Ideal-gas heat capacity of the carrier gases (N₂, O₂, Ar, CO₂, CH₄, H₂ and the Properties compounds) for enthalpy and the wet-bulb balance.
      5. E. W. Lemmon, R. T. Jacobsen, S. G. Penoncello, D. G. Friend, “Thermodynamic Properties of Air and Mixtures of Nitrogen, Argon, and Oxygen From 60 to 2000 K at Pressures to 2000 MPa”, J. Phys. Chem. Ref. Data 29 (3), 331–385, 2000sourceread 2026-11-21Molar mass and critical constants of air.
      6. Vaisala Oyj, “Humidity Calculator (online)”, humiditycalculator.vaisala.com, 2025sourcearchived copyread 2026-11-28Inspiration for the tool (quantities, gases, ± uncertainty, basic/advanced modes); its default case (air, 23 °C, 1013.25 hPa, 50 %rh) is the example and a test.
      7. Vaisala Oyj, “Humidity Conversions: Formulas and methods for calculating humidity parameters, B210973EN”, Vaisala technical eBook, 2025sourcearchived copyread 2026-11-28Method of the Vaisala calculator; Table 2: ITS-90 coefficients of the enhancement factor (Hardy 1998, Greenspan form) for water, supercooled water and ice; worked examples used as tests.
      8. B. Hardy, “ITS-90 formulations for vapor pressure, frostpoint temperature, dewpoint temperature, and enhancement factors in the range −100 to +100 °C”, Proc. Third International Symposium on Humidity and Moisture, Teddington, 1998read 2026-11-28Enhancement-factor coefficients for air (taken from the Vaisala eBook, Table 2, which cites this paper).
      9. D. Sonntag, “Important new values of the physical constants of 1986, vapour pressure formulations based on the ITS-90, and psychrometer formulae”, Zeitschrift für Meteorologie 40 (5), 340–344, 1990read 2026-11-28Saturation pressure over supercooled water below 0.01 °C (coefficients as printed in the Vaisala eBook, Table 1), scaled to meet IAPWS at the triple point.
      10. IAPWS, “Revised Supplementary Release on Saturation Properties of Ordinary Water Substance, SR1-86(1992)”, International Association for the Properties of Water and Steam, 1992sourcearchived copyread 2026-11-28Saturation pressure over liquid water (Eq. 1, Wagner & Pruß) from the triple point to the critical point; saturated-liquid density (Eq. 2) for the condensed-phase volume.
      11. IAPWS, “Revised Release on the Pressure along the Melting and Sublimation Curves of Ordinary Water Substance, R14-08(2011)”, International Association for the Properties of Water and Steam, 2011sourcearchived copyread 2026-11-28Saturation (sublimation) pressure over ice, Eq. 6; Table 3 value as a test.
      12. IAPWS, “Revised Release on the Equation of State 2006 for H2O Ice Ih, R10-06(2009)”, International Association for the Properties of Water and Steam, 2009sourcearchived copyread 2026-11-28Ice enthalpy and heat capacity at 273.16 K and 100 K (Table 6) for the ice-bulb energy balance below 0 °C.
      13. IAPWS, “Guideline on the Henry's Constant and Vapor-Liquid Distribution Constant for Gases in H2O and D2O at High Temperatures, G7-04”, International Association for the Properties of Water and Steam, 2004sourcearchived copyread 2026-11-28Henry's constants of N₂, O₂, Ar, CO₂, CH₄, H₂ and SF₆ (Eq. 3, Table 2) for the gas-solubility term of the enhancement factor; Table 6 values as tests.
      14. L. Greenspan, “Functional Equations for the Enhancement Factors for CO2-Free Moist Air”, J. Res. Natl. Bur. Stand. 80A (1), 41–44, 1976sourcearchived copyread 2026-11-28Form of the enhancement factor for air, 0.1 to 2 MPa, and its accuracy against Hyland (Tables 2, 3).
      15. R. W. Hyland, “A Correlation for the Second Interaction Virial Coefficients and Enhancement Factors for Moist Air”, J. Res. Natl. Bur. Stand. 79A (4), 551–560, 1975sourcearchived copyread 2026-11-28Virial equation for the enhancement factor (Eq. A-4) used for all gases; air coefficients (Eqs. 2, 4–6, 9, A-5 to A-7, Table 1) above 2 MPa and for the third virial terms of air; ice volume.
      16. A. H. Harvey, E. W. Lemmon, “Correlation for the Second Virial Coefficient of Water”, J. Phys. Chem. Ref. Data 33 (1), 369–376, 2004sourcearchived copyread 2026-11-28Second virial coefficient of water B_ww (Eq. 6, Table 4); Table 5 values as tests.
      17. A. H. Harvey, P. H. Huang, “First-Principles Calculation of the Air–Water Second Virial Coefficient”, Int. J. Thermophys. 28 (2), 556–565, 2007sourcearchived copyread 2026-11-28Water–gas cross second virial coefficients for N₂, O₂, Ar (Table I) and air (Eq. 5); air composition; Table III values as tests.
      18. R. J. Wheatley, A. H. Harvey, “Intermolecular potential energy surface and second virial coefficients for the water–CO2 dimer”, J. Chem. Phys. 134, 134309, 2011sourcearchived copyread 2026-11-28Water–CO₂ cross second virial coefficient (Eq. 4, Table I); Table II values as tests.
      19. O. Akin-Ojo, A. H. Harvey, K. Szalewicz, “Methane–water cross second virial coefficient with quantum corrections from an ab initio potential”, J. Chem. Phys. 125, 014314, 2006sourcearchived copyread 2026-11-28Water–methane cross second virial coefficient (Eq. 9); Table I values as tests.
      20. M. P. Hodges, R. J. Wheatley, G. K. Schenter, A. H. Harvey, “Intermolecular potential and second virial coefficient of the water–hydrogen complex”, J. Chem. Phys. 120 (2), 710–720, 2004sourcearchived copyread 2026-11-28Water–hydrogen cross second virial coefficient (Eq. 24, Table VI); Table VII values as tests.
      21. H. C. Van Ness, M. M. Abbott (R. H. Perry, D. W. Green, eds.), “Perry's Chemical Engineers' Handbook, 7th ed., Section 4: Thermodynamics”, McGraw-Hill, New York, 1997read 2026-11-28Generalized second virial coefficient (Eqs. 4-203, 4-208, 4-209) and combining rules (Eqs. 4-214 to 4-218) for the gas and, with a fitted k_ij, for water–gas pairs without published data.
      22. World Meteorological Organization, “Guide to Instruments and Methods of Observation (WMO-No. 8), Volume I, Chapter 4: Measurement of humidity, Annex 4.B”, WMO, Geneva, 2018 editionsourcearchived copyread 2026-11-28Psychrometer formula of the Assmann psychrometer (Eqs. 4.B.8, 4.B.9) and the definitions of relative humidity, dew and frost point.
      23. NOAA, NASA, USAF, “U.S. Standard Atmosphere, 1976 (NASA-TM-X-74335)”, U.S. Government Printing Office, Washington, 1976sourcearchived copyread 2026-11-28Pressure from elevation in the troposphere (up to 11 km); 1000 m → 89 875 Pa as a test.
      24. C. Guder, W. Wagner, “A Reference Equation of State for the Thermodynamic Properties of Sulfur Hexafluoride (SF6)”, J. Phys. Chem. Ref. Data 38 (1), 33–94, 2009sourceread 2026-11-28SF₆ critical constants and ideal-gas heat capacity (through CoolProp; c_p fitted 200–1000 K within 0.3 %).